Quetiapine Fumarate Extended-release Tablet Formulation Design Using Artificial Neural Networks
PDF
Cite
Share
Request
Original Articles
P: 213-221
December 2017

Quetiapine Fumarate Extended-release Tablet Formulation Design Using Artificial Neural Networks

Turk J Pharm Sci 2017;14(3):213-221
1. İstanbul University, Faculty of Pharmacy, Department of Pharmaceutical Technology, İstanbul, Turkey
2. İstanbul Kemerburgaz University, Faculty of Pharmacy, Department of Pharmaceutical Technology, İstanbul, Turkey
No information available.
No information available
Received Date: 14.10.2016
Accepted Date: 09.03.2017
Publish Date: 20.11.2017
PDF
Cite
Share
Request

ABSTRACT

Objectives:

This design study was implemented within the scope of the quality by design approach, which included the “International Conference on Harmonization” guidelines. We evaluated the quality of a modified-release tablet formulation of quetiapine fumarate, which was designed using artificial neural networks (ANN), and determined a new formulation that was similar to the reference product.

Materials and Methods:

Twelve different formulations were produced and tested. The reference product’s results and our experimental results were used as outputs for the training of the ANN programs of Intelligensys Ltd.

Results:

Dissolution tests were performed with the new formulation (F13) suggested by the INForm V.4 ANN program in three different pHs of the gastrointestinal system. The compliance of this formulation was confirmed by comparing the results with an f2 similarity test.

Conclusion:

Use of these programs supports research and development processes with multiple evaluation methods and alternative formulations may be determined faster and at lower cost.

INTRODUCTION

Quetiapine fumarate, a Biopharmaceutics Classification System class 2 drug, has been used in the treatment of schizophrenia. Its conventional and extended-release (ER) preparations are available on the market. Its ER formulations ensure safe, clinically effective treatment within accepted therapeutic intervals due to the decreased adverse effects and increased patient treatment adherence.1

ER formulations of quetiapine fumarate are prepared as membrane or matrix delivery systems. Mostly hydrophilic polymers are used in the formulation of ER systems. In particular, semi-synthetic cellulose derivatives, acrylic acid derivatives (carbomers), and natural polysaccharides are preferred.1,2,3,4

Carbopol 974P, an acrylic acid derivative, is used as a binding agent, which increases viscosity, film coating, and acts as a suspension agent material due to its capability of forming a gel at high viscosity.5 In addition, it controls the release rate of the drug through hydration and swelling mechanisms. Xanthan gum, a microbiologic polysaccharide, is produced by Xsanthomonas campestris with pure culture fermentation. It is also widely used as a stabilizer, suspension agent, viscosity increaser6, and as a matrix agent in ER formulations7 due to its capability to form a strong matrix structure.

The wet granulation method for the preparation of ER tablets is a common process in the pharmaceutical industry.8 Decreasing the time and cost of industrial scale production are the most important parameters in the development of ER tablets.9 In recent years, neural networks, fuzzy-logic programs, and multiple evaluation techniques have been used for the optimization of pharmaceutical formulations due to their advantages over classic formulation development strategies, such as being time saving and having lower cost. In addition, efficiency and quality are other important parameters in pharmaceutical development and production. There are some tools for these objectives such as faster analysis of data, efficient use of incomplete data banks, training of newly developed networks, exploring independent design areas away from complicated designs, finding the most useful choice, establishing restrictions in optimization, and producing useful norms.10

An artificial neural network (ANN) is an artificial intelligence tool that identifies arbitrary non-linear multi-parametric distinguishing functions directly from dependent and independent complex variables. Thus, it can separate signals and noise from experimental data.11,12 These programs evaluate dissolution profiles13 and take into account the physicochemical properties of products, such as friability and disintegration, and other consequential parameters that affect the release rate of drugs (particle size, type and amount of polymer, granulation technique, compression force, amount and type of lubricant).14

FormRules V3.32, a neural network-fuzzy logic program, INForm V.4 ANN, and V.4 gene expression programing (GEP) programs were used in the research and development studies.15 FormRules is a hybrid technology that is a very effective tool to obtain understandable rules from complex and non-linear data.16 The INForm programs use neural network-fuzzy logic and can perform optimization. Optimization is a mathematic method that searches for an “optimum” and most advantageous solutions to solve problems. As for INForm V.4 GEP, it is based on genetic algorithms, searching for the best holistic solutions according to the principle of ‘survival of the fittest’ in the multidimensional search space.17

Quality by Design (QbD) is included in the International Council for Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) Q8 guideline and, by enabling the use of data observed throughout the life cycle, it provides more scientific data regarding the product quality and to critical process knowledge.18 In the pharmaceutical industry, QbD is a very important contributor and emphasizes comprehension of process control, and quality products may be achieved more quickly with a systematic approach.19,20,21,22,23

In this study, ER formulations of quetiapine fumarate were prepared with xanthan gum or Carbopol 974P as matrix agents at their different ratios and an optimum formulation was developed that would be similar to the reference drug (Seroquel 200 mg XR tablet, AstraZeneca) in the market. In this context, the effect of granule size of bulk was investigated on the dissolution profiles of drug from formulated ER tablets. Critical quality characteristics and process parameter inputs were determined as polymer type-concentrations and sieving mesh sizes of dried granules, respectively. Then, a design study was conducted to follow the changes of the obtained outputs of the formulations and evaluated using FormRules V3.32, INForm programs.

EXPERIMENTAL

RESULTS

DISCUSSION

ER oral tablets are required to meet similar behaviors in the gastrointestinal tract in which physiologic fluids are at different pH values. Thus, in vitro dissolution studies are needed to be performed at three different pH values that mimic in vivo conditions. Following the evaluation of all dissolution studies and assessment of program data, formulation F1 was determined as the most similar to the reference product. The dissolution tests were performed in dissolution media at pH 1.2, 4.5, and 6.8. Although formulation F1 satisfied the ICH guideline24 limits at pH 1.2 and pH 6.8 (f2 values were 69 and 95, respectively), the f2 value for this formulation was calculated as 23 in pH 4.5 dissolution medium. Therefore, the formulation was not assessed as similar to the reference product.

Furthermore, the INForm programs recommended a new optimized formulation, which had the highest similarity to the reference product. However, the two formulations were very similar in terms of drug dissolution rates. Therefore, we chose the formula recommended by the ANN program, and the tablets were prepared according to this proposed formula (F13) in which xanthan gum was used as the polymer matrix agent [20.35% (w/w)] and the granule size was 1.0 mm.

To prove the similarity of the F13 formulation to the reference product, in vitro dissolution studies were performed using the dissolution method as explained above. The dissolution profiles of drug performed at three different pH values are shown in Figures 5, 6, 7. F2 similarity values of formulation F13 at pH 1.2, 4.5, and 6.8 were calculated as 76, 50, and 62, respectively.

The formulation selected by the FormRules (F1) and the INForm programs (F1) that showed the most similarity to the reference product did not show the expected performance in in vitro release studies. However, tablets with required performances were obtained in a shorter time with fewer trials due to the optimized formula suggestion of the INForm programs.

Similar programs have been used for the controlled-release formulation of clopidogrel using a matrix agent (Methocel K100M).38 In another study, the formulation components (diluent, binder, and their concentrations) and operation variables (type of the granulator and addition of the binder) of caffeine were evaluated and optimized formulas were obtained.39 In addition, the controlled-release tablets of theophylline were developed using a study of simultaneous optimization technique.40 All these studies indicated that these programs performed better estimation than those of current statistical methods.

It also should be kept in mind that these programs have some disadvantages. The most important is that models can be over-trained. In that case, the value of r2 might reach 0.95 or higher, and the background color turns to red. In such a case, model parameters are needed to be reviewed, checked, and retrained.

In our study, a release tablet formulation of quetiapine fumarate using a different polymer than that of its marketed product was optimized with lower cost and fewer trials, and in a shorter time by using ANN programs.

CONCLUSION

The greatest benefit of the FormRules program was understandable models, impressive experimental results and clearly described mathematical concept data. The program generated a rule base and contained all observations, experiences, and mathematical connections related to the subject, i.e., all information. The better and broader the rule base was prepared, the more precise and correct results were obtained. It presented data visually as three-dimensional graphs, which allowed us to extract the information quickly and easily, therefore enabling us to see which input was really effective on our formulation and also facilitating our decisions on how to obtain the most efficient results.

Using these programs, we attained information that tablets composed of xanthan gum were more successful than those that consisted of Carbopol 974P in extending the release of quetiapine fumarate from an ER tablet formulation. We evaluated the parameters including polymer concentration and mesh size of granules. A genetic algorithm-based optimization was performed and an optimized formula similar to the reference product was recommended. Without genetic algorithm-based optimization, more formulation trials would have been necessary to obtain the optimum formula. Consequently, it has been shown that an ER tablet formulation of quetiapine fumarate could be optimized quickly and at a lower cost.

Equipment

The equipment used included the following: tablet press machine (Rimek-Minipress-II, Karnavati-India), dissolution test apparatus (Distek Syringe Pump-Evolution 4300 Dissolution Sampler - USA), friability machine (Caleva FT-15, UK), hardness test apparatus (Caleva THT-15, UK), magnetic stirrer (Hei-standard, Heidolph MR), pH meter (Seven Easy, Mettler Toledo-Switzerland), HPLC (Waters e2695 PDA detector, Waters-USA), ultrasonic bath (RK 1028 CH, Bandelin Sonorex Super), wet stoker (Mettler LP16, Mettler), oven (Nuve) KD 200, balance (Mettler PM100, Mettler-Switzerland), mechanical stirrer (Stirrer LH, Velp Scientifica), FormRules V3.32, INForm V.4 ANN, and INForm V.4 GEP softwares (INtelligent Ltd-UK).

Ingredients

Quetiapine (fumarate salt) (Aurobindo Pharma Limited, Unit-XI- India), MCC 101 (FMC Biopolymer, Newark, USA), lactose monohydrate (DMV, Netherlands), sodium citrate (Merck, Germany), Carbopol 974P (Lubrizol, USA), xanthan gum (JUNGBUNZLAUER, Switzerland), Mg stearate (FACI, Genoa, Italy) were pharma grade and all other chemicals were analytical grade.

Data set

In this study, polymer type, polymer concentrations, and sieving mesh size parameters were described as independent variables (inputs); tablet weight, tablet hardness, friability, assay and dissolution percentage (%) at all of the time points used in the dissolution tests (30 min and 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, and 24 hours) were described as dependent variables (outputs). Therefore, two different polymer types (xanthan gum and Carbopol 974P), three different concentrations for each polymer [according to the preliminary study findings for xanthan gum; 16%, 24.5%, and 31% (w/w), for Carbopol 974P; 10%, 23%, and 50% (w/w)], and two different sieving mesh sizes (0.8 and 1.4 mm) for dry granules were suggested.

A systematic scientific approach was applied to control tablet production variables in the process design. For this purpose, a study design was formed by determining the critical parameters for the formulation within the framework of the QbD approach. These variables were also formed as the critical quality attributes. The main goal of our study was to be able to understand the possible effects of these parameters on the release profiles of ER quetiapine fumarate tablets. Then, training of the FormRules V.3.32 and INForm programs was conducted with the observed test results. The results showed that formulation F1 was the most similar formulation to the reference product chosen by the programs. In addition, formulation F13 was suggested as a new formula after optimization from INForm programs. Afterwards, F1 and F13 dissolution profiles were tested at three different pH values, as proposed by the ICH Q6 guidelines (pH 1.2, 4.5, and 6.8).

The dissolution profiles of F1 and F13 were compared with the reference product to determine whether it adhered to the compliance criteria.24 The critical quality and process parameters (inputs) and quality target product profiles (outputs) in the process design are shown in Table 1, and the visualizations of the interactions between these properties are shown with their positions in a fishbone diagram in Figure 1.

Tablet formulation and manufacturing

All tablet formulations containing 230 mg of quetiapine fumarate were prepared with the wet granulation method (Table 2). A flow diagram of the production method is shown in Figure 2. In brief, quetiapine fumarate, lactose monohydrate, sodium citrate, microcrystalline cellulose 101, and the polymer (xanthan gum or Carbopol 974P) were weighed and sieved as the internal phase and mixed in a mechanical mixer for 10 min. Granulation was achieved by slowly adding distilled water to the dry mixture; when the granules reached the desired consistency, they were sieved with a 4-mm mesh screen. The wet granules were dried in an oven at 45°C and then divided into two parts; one part was sieved through a 0.8 mm mesh screen and the other was sieved through a 1.4 mm mesh screen. Magnesium stearate was sieved and added to the granules as the outer phase. The product was mixed in a mechanical mixer for 5 min and tablets were compressed using a tablet compressor (Karnavati Tablet Compression Machine, India).

Tests for prepared tablets

Weight variation

For all formulations, 10 tablets were weighed one-by-one on a precision scale (Mettler-Switzerland), and average weight, standard deviation, and relative standard deviation values were calculated.

Determination of hardness

Ten tablets were taken from all formulations. Tablet hardness was measured using a hardness testing instrument (Caleva, UK). Average hardness, standard deviation, and relative standard deviation values were calculated.

Friability test

From all formulations, 10 tablets were weighed and placed in a friability tester (Caleva, UK); the instrument was run, a test was conducted at 25 rpm for 4 min, and the tablets were weighed after the procedure. Percentage weight loss was calculated according to Equation 125:

Where,

Wi = initial weight of tablets

Wf = weight after friabilityv

Assay

HPLC (Waters) was used for quetiapine fumarate analysis.26 Method parameters are summarized as follows;

Detector: PDA

Mobile phase: pH 6.5 phosphate buffer-acetonitrile (60:40; v/v)

Column: Cromasil 100, C18 (250x4.6 mm), 5 µm

Wavelength: 225 nm

Flow rate: 1.5 mL/min

Retention time: 4 min

The determination of active substance amount in ER tablets containing 230 mg of quetiapine fumarate and dissolution rate test method validation (accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, robustness, system suitability testing) were performed according to the ICH Q2 guidelines.27

Dissolution tests

For the similarity between the developed ER formulations of quetiapine fumarate and reference product, a dissolution test was performed in the medium (0.1 N HCl, 900 mL) registered in the literature. USP apparatus II with the paddle method was used for this test at 37°C±0.5 at 50 rpm.28 The experiments were performed six times. The analysis of samples, which were taken from the dissolution medium at the determined time intervals (at the end of 30 min and 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, and 24 hours) was performed and fresh dissolution medium was added. Dissolution tests were also conducted under the same conditions using different dissolution media including buffered solutions at pH 1.2, pH 4.5, and pH 6.8.

Evaluation of dissolution data

The similarity of dissolution profiles of ER quetiapine fumarate tablet formulations and that of the reference ER product were determined using the f2 test (similarity factor)29 given in Equation 2:

Where Rj and Tj are the cumulative percentages dissolved at each of the selected “n” time points of the reference and test product, respectively. For similarity of the formulations, this factor should be between 50 and 100.

Software tools

Commercial artificial intelligence software tools were used to interrogate the production data generated in the studies. FormRules V3.3230 and INForm programs are software packages developed by Intelligensys Ltd., UK.

Analytical validation results

Linearity concentrations range between 10-120%. The limit of detection value was 5.0 mg/mL and the limit of quantification value was 16.667 mg/mL. The other validation procedure results are shown in Table 3.

Physical tests results

Physical tests of the formulations were performed. The average diameter of the tablets was between 17.88-17.99 mm for formulations composed of both polymers, and the thickness values were between 5.36-6.01 mm for tablets prepared with xanthan gum, and between 5.21-8.20 mm for the Carbopol 974P series. The assay results of the tablets were between 98.07-102.00%. Other physical tests results are shown in Table 4. All parameters were within the Pharmacopoeia limits.31,32

Dissolution tests results

The dissolution profiles of all formulations were compared with that of the reference product. All dissolution studies were performed in the best-dissolved medium of quetiapine fumarate for 24 hours (pH 1.2) (Figure 3). The similarity factor (f2) values for all formulations were calculated and are shown as a histogram in Figure 4. The f2 similarity values of formulations coded with F1, F2, F3, F4, F6, and F12 were calculated as 69, 52, 63, 68, 68, and 55, respectively. The formulations coded as F1, F4, and F6 were highly similar to the reference product.

FormRules program results

Training of programs was conducted using the physical and chemical test results of all formulations, and the results were evaluated. The r2 value was 0.99 for the average weight data and the polymer concentration was the dependent variable. Polymer concentrations and hardness values can influence each other moderately, as such, the dependent variables and models also have influence.

The dependent variables of polymers are highly important for the dissolution rate of drugs. If the polymer type and concentration change, the drug dissolution profiles would also change. When Carbopol 974P was used, the dissolution percentage of drug was high, and the dissolution behavior of drug was not affected due to the particle size.33 When xanthan gum was used as the polymer, the dissolution percentage of drug was decreased.34,35 The change in drug release by polymer type observed in this study complies with the literature. The release of active substance from hydrophilic matrix tablets is related to a product’s own behavior, and the typical characteristics of the drug together with the properties of the polymer, i.e., molecular weight, hydrophilicity, and degree of cross-linking.36 An inverse proportionality was detected between polymer concentration and dissolution percent of drug. Therefore, it was suggested that in vitro release behavior of drug was related to polymer concentration. Increased polymer concentration led to decreased diffusion of drug in the dissolution medium. Thus, the types and concentrations of polymers are crucial factors that affect dissolution of drugs.37

The similarity values were obtained using the FormRules program. Formulation F1 was found as the most similar to the reference product (100%). This formulation also showed the highest similarity to the reference product (69%) in terms of f2 similarity factor when the dissolution study was performed at pH 1.2.

INForm program results

When the r2 values were high, the model was well-built, and the program was conditioned. F1 was the most similar formulation to the reference product according to the INForm data.