VALIDATED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF LAMOTRIGINE IN HUMAN PLASMA AND SALIVA
PDF
Cite
Share
Request
Original Article
P: 213-224
December 2010

VALIDATED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF LAMOTRIGINE IN HUMAN PLASMA AND SALIVA

Turk J Pharm Sci 2010;7(3):213-224
1. Gazi University, Faculty Of Pharmacy, Department Of Pharmaceutical Technology, 06330 Etiler-Ankara, Turkey
No information available.
No information available
Received Date: 17.09.2009
Accepted Date: 22.01.2010
PDF
Cite
Share
Request

ABSTRACT

A simple, sensitive and precise high performance liquid chromatographic assay for lamotrigine (LTG) is described. Good chromatographic separation was achieved using a 5 um ACE-5 CI8 reverse-phase column and a mobile phase consisting of methanol:acetonitrile: 0.01 M potassium phosphate monobasic (30:15:55, v/v/v) adjusted to pH 6.3 and delivered at a flow rate of 1 mL/min. Quantification was performed by measurement of the UV absorbance at a wavelenght of 304 nm. The method was linear in the range of 0.1-6.2 ug/mL with a coeffient of determination, (r2 = 0.999). The retention time of LTG was 6.8 and 6.2 min in plasma and saliva, respectively. The limit of quantification was 0.10 ug/mL. Recovery from plasma and saliva ranged from 97 to 98 and 96 to 105 %, respectively. Between-day and within day precision expressed as CV % in plasma and saliva were in the range of 0.26 to 6.8. The method was showed to be appropriate for pharmacokinetic (PK) studies and monitoring LTG in saliva and plasma samples.